Shenzhen Eurostars Technology Co., Ltd. >> 450kw Air Cooled Screw Chiller Industrial Air Conditioner

450kw Air Cooled Screw Chiller Industrial Air Conditioner

450kw Air Cooled Screw Chiller Industrial Air Conditioner
Price: US $ 12000-65000/Piece
Min Order: 1/Piece
Pay Type: L/C,T/T,Western Union
Prod Model: ESGA series
Compressor: Hanbell or Bitzer
Evaporator: Shell and Tube
Condenser: Fin Type
Controller: Scm, PLC Is Optional
Refrigerant: R22/R407c/R404A/R134A
Expansion Valve: Danfoss/Emerson
OEM: Available
Dom: Available
Overseras Service: Available
Type: Air-Cooled
Certification: SGS
Condition: New
Compressor Number: 1 or 2
Selected Voltage: 230V-460V/50-60Hz

Product Description

1.Eurostars air cooled screw type water chiller 
a)Low Noise
b)High Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
g)CE certificated
 
2.Eurostars Water Chiller Features-air cooled screw type waater chiller
1).The Chiller cooling capacity with a widely range
2). Adopt good quality famous brand HANBELL  or Bitzer compressor,high efficiency, low noise, less 
  wearing and long life
3).With high efficiency condener and evaporator
4). World famous brand parts: such Danfoss/ ALCO expansion valve, FUJI contactor other brand like PUNP, Schneider,Siemens;
5). Water chillers have high COP;
6). Stable quality, long using life. 
7).Heat recovery(optional)can help user produce free hot water, which can be 55C
8). Can be widely used in different area.
9). Strong unit base frame ensured the equipment stable operation 
10). Adopt leading brand PLC or SCM controller
11). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
12).Standard model exclude water tank and water pump;but it can be custom-made based on client requirement,such as including chilled water pump,hot water pump and hot water tank;
13).Refrigerant is R407C,R22,but R404A,R134A also available.
14).Power and frequency supply:380~415V-3PH-50HZ;Can customize 220~480V-3PH-60HZ;
15). Chilled water range: 5°C to 20°C
 

3.Eurostars water chiller protection devices
1)Phase reversion protection, 
2)Phase lack protection, 
3)Overload current protection,
4)Discharge air temp. protection, 
5)Low & High pressure protection, 
6)Low temp. protection, 
7)Water flow protection(interface reserved)
 
 
4.Eurostars chiller technical parameter

4.1Refrigerant-R22
<
Air Cooled Chiller Unit (Screw Type Compressor-one compressor)
 Model     ESGA-40ISTS60ISTS80ISTS90ISTS105ISTS115ISTS125ISTS
Rated Cooling CapacityKW143204273322373403444
USRT40.67 58.02 77.65 91.58 106.09 114.62 126.28 
X 1000Kcal/h122.98 175.44 234.78 276.92 320.78 346.58 381.84 
 Comp. lnput Power×Qty (KW)39.3×153.7×171.2×179.7×192.3×1100.8×1109.8×1
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit1
Capacity Control (%)0, 66, 1000, 50, 75, 100
Refrigerant Charge (Kg)30425668788493
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)2-1/2"3"3"3"4"4"4"
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)24.60 35.09 46.96 55.38 64.16 69.32 76.37 
Water Pressure drop (kPa) 28334855616466
Axial FanAir Flow×1000m3/h40.256.880.485.2120.6120.6160.8
Power×Qty (KW)2.0×21.2×42.0×41.2×62.0×62.0×62.0×8
Running Noise dB(A)68686868727272
Total Weight (Kg)1160173025902670275029303160

<
Air Cooled  Chiller Unit (Screw Type Compressor-two compressors)
 Model     ESGA-140IDTS155IDTS185IDTS195IDTS210IDTS230IDTS255IDTS
Rated Cooling CapacityKW498546644682746806888
USRT141.64 155.29 183.16 193.97 212.17 229.24 252.56 
X 1000Kcal/h428.28 469.56 553.84 586.52 641.56 693.16 763.68 
 Comp. lnput Power×Qty (KW)65.4×271.2×279.7×283.4×292.3×2100.8×2109.8×2
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit2
Capacity Control (%)0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg)104112136142156168186
Condenser Ripple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)5"5"3"×23"×24"×24"×24"×2
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)85.7 93.9 110.8 117.3 128.3 138.6 152.7 
Water Pressure drop (kPa) 42544452545565
Axial FanAir Flow×1000m3/h160.8160.8170.4241.2241.2241.2321.6
Power×Qty (KW)2.0×82.0×81.2×122.0×122.0×122.0×122.0×16
Running Noise dB(A)72727272757575
Total Weight (Kg)4430455053405420550058606320

<
Air Cooled Chiller Unit with Heat Recovery (Screw Type Compressor-one compressor)
 Model     ESGA-40ISVTS60ISVTS80ISVTS90ISVTS105ISVTS115ISVTS125ISVTS
Rated Cooling CapacityKW143204273322373403444
USRT40.67 58.02 77.65 91.58 106.09 114.62 126.28 
X 1000Kcal/h122.98 175.44 234.78 276.92 320.78 346.58 381.84 
 Comp. lnput Power×Qty (KW)39.3×153.7×171.2×179.7×192.3×1100.8×1109.8×1
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit1
Capacity Control (%)0, 66, 1000, 50, 75, 100
Refrigerant Charge (Kg)30425668788493
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)2-1/2"3"3"3"4"4"4"
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)24.60 35.09 46.96 55.38 64.16 69.32 76.37 
Water Pressure drop (kPa) 28334855616466
Axial FanAir Flow×1000m3/h40.256.880.485.2120.6120.6160.8
Power×Qty (KW)2.0×21.2×42.0×41.2×62.0×62.0×62.0×8
Running Noise dB(A)68686868727272
Total Weight (Kg)1160173025902670275029303160
Running Weight(Kg)1270192028102900302032403450
Heat Recovery Parameters
Refrigerant Charge (Kg)32445971808796
Heat Reclaimed Volume (kw)KW43 61 82 97 112 121 133 
USRT12.20 17.41 23.29 27.47 31.83 34.39 37.88 
X 1000Kcal/h36.89 52.63 70.43 83.08 96.23 103.97 114.55 
Heat RecovererDia.of Pipe (inch)1-1/2"1-1/2"1-1/2"2"2"2"2"
Water Side Max Pressure  (MPa)
Reclaimed  Water Flow (m3/h)7.4 10.5 14.1 16.6 19.2 20.8 22.9 
Water Pressure drop (kPa) 24232727262626
Total Weight (Kg)1240181026902770313032403490

<
Air Cooled Chiller Unit with Heat Recovery (Screw Type Compressor-two compressor)
 Model     ESGA-140IDVTS155IDVTS185IDVTS195IDVTS210IDVTS230IDVTS255IDVTS
Rated Cooling CapacityKW498546644682746806888
USRT141.64 155.29 183.16 193.97 212.17 229.24 252.56 
X 1000Kcal/h428.28 469.56 553.84 586.52 641.56 693.16 763.68 
 Comp. lnput Power×Qty (KW)65.4×271.2×279.7×283.4×292.3×2100.8×2109.8×2
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit2
Capacity Control (%)0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg)104112136142156168186
Condenser Ripple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)5"5"3"×23"×24"×24"×24"×2
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)85.7 93.9 110.8 117.3 128.3 138.6 152.7 
Water Pressure drop (kPa) 42544452545565
Axial FanAir Flow×1000m3/h160.8160.8170.4241.2241.2241.2321.6
Power×Qty (KW)2.0×82.0×81.2×122.0×122.0×122.0×122.0×16
Running Noise dB(A)72727272757575
Total Weight (Kg)4430455053405420550058606320
Running Weight(Kg)4750497058005950604064806900
Heat Recovery Parameters
Refrigerant Charge (Kg)110118142148160174192
Heat Reclaimed Volume (kw)KW149.4163.8193.2204.6223.8241.8266.4
USRT42.49 46.59 54.95 58.19 63.65 68.77 75.77 
X 1000Kcal/h128.48 140.87 166.15 175.96 192.47 207.95 229.10 
Heat RecovererDia.of Pipe (inch)2-1/2"2-1/2"2"×22"×22"×22"×22"×2
Water Side Max Pressure  (MPa)
Reclaimed  Water Flow (m3/h)25.7 28.2 33.2 35.2 38.5 41.6 45.8 
Water Pressure drop (kPa) 26262727303034
Total Weight (Kg)4790491054905570566060206480

4.2 Refrigerant R407C

<
Air Cooled Chiller Unit (Screw Type Compressor-one compressor)
 Model     ESGA-40ISTN55ISTN75ISTN90ISTN100ISTN110ISTN120ISTN
Rated Cooling CapacityKW136198263311360393424
USRT38.68 56.31 74.80 88.45 102.39 111.77 120.59 
X 1000Kcal/h116.96 170.28 226.18 267.46 309.60 337.98 364.64 
 Comp. lnput Power×Qty (KW)37.2×151.8×168.7×176.4×189.2×197.5×1106.8×1
Refrigerant R407C
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit1
Capacity Control (%)0, 66, 1000, 50, 75, 100
Refrigerant Charge (Kg)30425668788493
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)2-1/2"3"3"3"4"4"4"
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)23.4 34.1 45.2 53.5 61.9 67.6 72.9 
Water Pressure drop (kPa) 28334855616466
Axial FanAir Flow×1000m3/h40.256.880.485.2120.6120.6160.8
Power×Qty (KW)2.0×21.2×42.0×41.2×62.0×62.0×62.0×8
Running Noise dB(A)68686868727272
Total Weight (Kg)1160173025902670275029303160

<
Air Cooled Chiller Unit (Screw Type Compressor-two compressor)
 Model     ESGA-140IDTN150IDTN175IDTN185IDTN205IDTN225IDTN240IDTN
Rated Cooling CapacityKW482526622658720786848
USRT137.09 149.60 176.91 187.14 204.78 223.55 241.18 
X 1000Kcal/h414.52 452.36 534.92 565.88 619.20 675.96 729.28 
 Comp. lnput Power×Qty (KW)62.4×268.7×276.4×280.3×289.2×297.5×2106.8×2
Refrigerant R407C
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit2
Capacity Control (%)0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg)104112136142156168186
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)5"5"3"×23"×24"×24"×24"×2
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)82.90 90.47 106.98 113.18 123.84 135.19 145.86 
Water Pressure drop (kPa) 42544452545565
Axial FanAir Flow×1000m3/h160.8160.8170.4241.2241.2241.2321.6
Power×Qty (KW)2.0×82.0×81.2×122.0×122.0×122.0×122.0×16
Running Noise dB(A)72727272757575
Total Weight (Kg)4430455053405420550058606320

     <
Air Cooled Chiller Unit with Heat Recovery (Screw Type Compressor-one compressor)
 Model     ESGA-40ISVTN55ISVTN75ISVTN90ISVTN100ISVTN110ISVTN120ISVTN
Rated Cooling CapacityKW136198263311360393424
USRT38.68 56.31 74.80 88.45 102.39 111.77 120.59 
X 1000Kcal/h116.96 170.28 226.18 267.46 309.60 337.98 364.64 
 Comp. lnput Power×Qty (KW)37.2×151.8×168.7×176.4×189.2×197.5×1106.8×1
Refrigerant R407C
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit1
Capacity Control (%)0, 66, 1000, 50, 75, 100
Refrigerant Charge (Kg)30425668788493
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)2-1/2"3"3"3"4"4"4"
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)17.425.333.739.946.150.454.3
Water Pressure drop (kPa) 28334855616466
Axial FanAir Flow×1000m3/h40.256.880.485.2120.6120.6160.8
Power×Qty (KW)2.0×21.2×42.0×41.2×62.0×62.0×62.0×8
Running Noise dB(A)68686868727272
Total Weight (Kg)1160173025902670275029303160
Running Weight(Kg)1270192028102900302032403450
Heat Recovery Parameters
Refrigerant Charge (Kg)32445971808796
Heat Reclaimed Volume (kw)KW40.8 59.4 78.9 93.3 108.0 117.9 127.2 
USRT11.60 16.89 22.44 26.54 30.72 33.53 36.18 
X 1000Kcal/h35.09 51.08 67.85 80.24 92.88 101.39 109.39 
Heat RecovererDia.of Pipe (inch)1-1/2"1-1/2"1-1/2"2"2"2"2"
Water Side Max Pressure  (MPa)
Reclaimed  Water Flow (m3/h)7.0 10.2 13.6 16.0 18.6 20.3 21.9 
Water Pressure drop (kPa) 24232727262626
Total Weight (Kg)1240181026902770313032403490
<
Air Cooled Chiller Unit with Heat Recovery (Screw Type Compressor-two compressor)
 Model     ESGA-140IDVTN150IDVTN175IDVTN185IDVTN205IDVTN225IDVTN240IDVTN
Rated Cooling CapacityKW482526622658720786848
USRT137.09 149.60 176.91 187.14 204.78 223.55 241.18 
X 1000Kcal/h414.52 452.36 534.92 565.88 619.20 675.96 729.28 
 Comp. lnput Power×Qty (KW)62.4×268.7×276.4×280.3×289.2×297.5×2106.8×2
Refrigerant R407C
Power Supply 3φ-380V-50HZ
Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit2
Capacity Control (%)0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg)104112136142156168186
CondenserRipple Aluminum Fins Around Copper Pipe
EvaporatorDia.of Pipe (inch)5"5"3"×23"×24"×24"×24"×2
Water Side Max Pressure  (MPa)1
Chilled  Water Flow(m3/h)82.90 90.47 106.98 113.18 123.84 135.19 145.86 
Water Pressure drop (kPa) 42544452545565
Axial FanAir Flow×1000m3/h160.8160.8170.4241.2241.2241.2321.6
Power×Qty (KW)2.0×82.0×81.2×122.0×122.0×122.0×122.0×16
Running Noise dB(A)72727272757575
Total Weight (Kg)4430455053405420550058606320
Running Weight(Kg)4750497058005950604064806900
Heat Recovery Parameters
Refrigerant Charge (Kg)110118142148160174192
Heat Reclaimed Volume (kw)KW144.60 157.80 186.60 197.40 216.00 235.80 254.40 
USRT41.13 44.88 53.07 56.14 61.43 67.06 72.35 
X 1000Kcal/h124.36 135.71 160.48 169.76 185.76 202.79 218.78 
Heat RecovererDia.of Pipe (inch)2-1/2"2-1/2"2"×22"×22"×22"×22"×2
Water Side Max Pressure  (MPa)
Reclaimed  Water Flow (m3/h)24.87 27.14 32.10 33.95 37.15 40.56 43.76 
Water Pressure drop (kPa) 26262727303034
Total Weight (Kg)4790491054905570566060206480

5.Eurostars water chiller series
-Commercial Water Cooled Chiller
-Scroll type water cooled water chiller
-Screw type water cooled water chiller
-Flooded type water cooled water chiller
 
-Commercial Air Cooled Chiller
-Scroll type air cooled water chiller
-Screw type air cooled water chiller
 
-Industrial Chiller
-Air cooled industrial chiller(with heat recovery)
-Water cooled industrial chiller(with heat recovery)
-Glycol chiller (with heat recovery)
 
 
We, Eurostars Group, is a modern hi-tech enterprise, specializing in air conditioning research, development, production, sales and engineering services.

The current product lines range from central air conditioning refrigeration system for commercial and industrial use to dehumidification system, including centrifugal series, scroll series and air terminal series. We manufacture products such as water/air cooled screw chiller unit, modular chiller unit, water/ground/air source heat pump unit, low temperature ambient chiller, industrial chiller, glycol chiller, condensing unit, rooftop air conditioning unit, water/air cooled heat pump packaged air conditioner, constant temperature and humidity unit, air handling unit, and fan coil unit. We strive to become the best air conditioner manufacturer that offer wide range of products and competitive price for meeting the customers' real demand.

Perfect quality depends on the professional technical support team and standardized operation flow. Eurostars owns advanced production and testing equipments, including assembly production lines for large and small units respectively, heat exchanger pipeline, large spraying pipeline, CNC processing center, CNC punching and bending machine, pipe expanding machine, automatic welder, large mational-level testing center for water cooled and air cooled chiller, national-level testing center for household cold water (heat pump) unit, etc., thus ensuring product quality and services.

Send your message to this manufacturer

  • Shenzhen Eurostars Technology Co., Ltd.

More >

Other Valve Products with This Manufacturers

Look for Similar Items by Category: