Prod Model: |
YLC-008 |
Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Bactericidal Efficienc: |
98% Kill Total Coliforms |
Medium Material: |
PP (Propene Polymer) |
Lifespan Of UV Lamp: |
9000-12000 Hours |
Interface Type: |
Flange or Thread |
Flow Rate: |
0.3--1000 Ton/Hour |
Alert System For Lamp: |
One Set |
System Working Pressure Resistance: |
(0.6 MPa)6kg/Cm2 |
Raw Water Supplying: |
Running Water |
Brand Of Ballast: |
Beasun |
Voltage: |
110V/220V/380V |
Product Description
House Water Purifier Ultraviolet Water Sterilizer
Application
1. Food processing industry, including juices, milk, drinks, beer, practical oil and canned food.
2. Electronic industry.
3. Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4. Households building, residential, office buildings, hotels, restaurants, water factories.
5. Purification and disinfection of shellfish, fish cleaning and disinfection
6. Military camp, field water supply system
7. Urban wastewater disinfection.
8. Swimming pool, other recreational water disinfection
9. Thermal power, nuclear power plant industrial, central air conditioning system cooling water.
10. Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11. Sea water, fresh water breeding, aquaculture water
12. Agricultural water disinfection
UV specification
Product application
Ultraviolet light treatment is a widely recognized and proven method of disinfection of water and has several advantage over other disinfection methods such as chlorination, ozonation, etc. UV light does not add anything to the water, such as, undesirable color, odor, taste, or flavor, nor does it generate harmful byproducts. It adds only energy in the UV radiation. Also, UV disinfection requires only a fraction of the contact times required by other disinfection methods. It is fast, efficient, effective, economical and environmentally-friendly.
Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)
DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)
As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰
Packaging & Shipping
Normal Packing: Wooden boxes packaging into container
FOB TO Shanghai
Our Services
After-sale service: 800-827-87-226
Guarantee period: 6 month
Company Information
Jiangsu YLD Water Processing Equipment Co., Ltd. *, will be 20-22 May 2014 to participate in the Shanghai New International Exhibition Center IE expo 2014 Expo Central China Water Show, Booth No.: N3 Hall 3134, Address: Shanghai New International Expo Center ( 2345 Longyang Road )
Seventh AQUATECH CHINA Shanghai International Water Exhibition Venue: Shanghai World Expo Exhibition (Shanghai International Exhibition Road, 1099), the time June 25, 2014 -27 days, Booth No.: 3.423
Model | Capacity (m3/hour) | Power (Watts) | Incoming and outcoming water pipes (Nominal/ British system) | System pressure resistance (Kg/cm²) | UV light fault Alarm | Dimension of the reactor (cm) L×W×H | Dimension of the control cabinet (cm) | Anchor screws | Transport weight(Kg) |
YLCn-005 | 0.3 | 16 | 1/2″ | 6 | Has | 30×6×11 | | | 5 |
YLCn-008 | 1 | 25 | 1/2″ | 6 | Has | 47×6.3×11 | | | 10 |
YLCn-050 | 2 | 40 | 1″ | 6 | Has | 100×9×20 | Φ8.9×25 (d×L) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4″ | 6 | Has | 100×11×23 | 69×4×Φ1 | 30 |
YLCn-200 | 8 | 120 | 1+1/2″ | 6 | Has | 100×15.9×30 | Φ8.9×45 (d×L) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2″ | 6 | Has | 100×15.9×32 | 69×7×Φ1 | 40 |
YLC-050 | 2 | 40 | DN25/1″ | 6 | Has | 100×8.9×30 | 25×30×12 (W×H×D) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/11/4″ | 6 | Has | 100×10.8×30 | 60×4×Φ1 | 50 |
YLC-200 | 8 | 120 | DN40/11/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 60 |
YLC-300 | 12 | 160 | DN50/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 70 |
YLC-360 | 15 | 200 | DN65/21/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 120 |
YLC-500 | 20 | 240 | DN65/21/2″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 130 |
YLC-600 | 25 | 280 | DN80/3″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 140 |
YLC-700 | 30 | 320 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 150 |
YLC-1000 | 40 | 360 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 160 |
YLC-1200 | 50 | 400 | DN125/5″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 180 |
YLC-1500 | 60 | 420 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 210 |
YLC-2000 | 80 | 560 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 220 |
YLC-2500 | 100 | 700 | DN150/6″ | 6 | Has | 170×27.3×57 | 60×128×30 (W×H×D) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 300 |
YLC-4000 | 150 | 1120 | DN200/8″ | 6 | Has | 173×32.5×65 | 120×20×Φ1.6 | 325 |
YLC-5000 | 200 | 1400 | DN200/8″ | 6 | Has | 173×37.7×72 | 120×22×Φ1.6 | 350 |
YLC-7000 | 300 | 2100 | DN250/10″ | 6 | Has | 175×42.6×80 | 120×24×Φ2.0 | 400 |
YLC-10K | 400 | 2520 | DN250/10″ | 6 | Has | 176×52.9×95 | 60×150×40 (W×H×D) | 120×22×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12″ | 6 | Has | 176×78×110 | 120×32×Φ2.4 | 600 |
YLC-20K | 800 | 3920 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
YLC-25K | 1000 | 4760 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
Jiangsu YLD Water Processing Equipment Co., Ltd. is a high-tech enterprise, specialized in the research, development, design, manufacture, installation, technical consultation and personnel training.
We mainly produce electronic scale removal, UV sterilization, filtration, softening and cyclone grit removal technology and equipment. With strong technical force and rich experience, our company strictly implements ISO9001 system in the plan and management. "High technology leads to market development" is our basic concept.
We have extensively cooperated with domestic key universities, research institutions and foreign professional manufacturers, such as DOW (Dow) Chemical Co., Ltd., HYDRANAUTICS (Hydranautics) Company, Company (a professional manufacturer of multi-stage pumps), MILTONROY (Milton) Corporation (a metering pump manufacturer), the US Soft Controller KINETICO and OSMONICS, We have also fully introduced advanced technology. Thus, our technology is always in the leading domestic level. Over the years, our company has specialized in a variety of water treatment equipment for food, beverage, pharmaceutical, hospital, precision electronic, fine chemical, electricity, painting and surface cleaning industries.
Our "LYD" high-quality products at reasonable prices and perfect after-sales services have won great trust from worldwide customers,
We are willing to cooperate with the friends from all over the world and creat fine future together!