Working Principle:
Heat purge regeneration desiccant air dryer is working with regenerative air and warm the desiccant then re-use it. It not only improves the regeneration effect also reduces air consumption with energy-saving function.
Performance:
Regeneration air capacity: ≤7%
Inlet Oil Content: ≤0.1PPM
Working Pressure: 0.6~0.95MPa
Dew Point Pressure: -20~-40ºC
Desiccant: Activated Alumina
Control Method: Micro PC Automatically
Installation: Indoor Location, anchor bolt installation
Standard working conditions
-Inlet temperature: 2~45ºC
-Nominal inlet pressure: 0.069MPa
Screw Standard: GB/T7306
Power Consumption: 80% of electric heat
Flange standard: HG20592
Options:
-Desiccant: molecule sieve
-Full dew point-controlled
-Dual pre-and after filters.
-Remote communicating
Features of Desiccant Air Dryer:
According to the demand on the air consumption for regeneration, the desiccant air dryer are divided into no heat type and micro heat(heat purge) type. Heatless regeneration desiccant air dryer is equipment to dry compressed air by using pore shape desiccant to dry water molecule sieve; it is based on the principle of Pressure Swing Adsorption. Heat purge regeneration desiccant air dryer is working with regenerative air and warm the desiccant then re-use it. It not only improves the regeneration effect also reduces air consumption with energy-saving function.
The desiccant air dryer uses molecular sieve or alumina as the desiccant to adsorb moisture in the compressed air under a certain working pressure. Then, re-lead a part of dry air from the dryer outlet for desorption at atmospheric pressure. One tower is for water adsorption and another for desorption and regeneration. The two towers can work continuously to provide the air consuming equipment with dry, clean compressed air.
The twin tower dryer is widely used for outdoor applications requiring compressed air in cold areas, indoor applications requiring compressed air of long-distance pipeline transportation, and manufacturing process requiring deep drying, such as advanced spraying, jet flow control, polyester spinning etc.
Why Broatek?
1. Wide product range. Shanghai Broatek provide various kinds of options for desiccant regenerated air dryers, including heatless air dryer, heat purge air dryer, compressed air dryer, heat purge with blower air dryer and combined type air dryer. Working pressure is from standard, middle and high pressure. Capacity from 0.8/min~500m/min. Dew point is from -12ºC~-70ºC. Two tower shift period is from 4min~8hours.Desiccant use activated alumina or molecule sieve. Control method we use PLC micro pc. And the power is from 220v/1ph/50HZ~380v/3ph/50HZ etc. We can also make your special requirement for zero loss regeneration HOC.
2. Strict product testing: To ensure the product quality, we introduced advanced testing equipment to test air flow, pressure, intake temperature, dew point and other technical data.
3. Air system:
-To eliminate Channeling phenomenon: The air distributor in desiccant tower is using big section stainless steel diffuser, this is guarantee the air evenly go through the desiccant, avoid the channeling phenomenon, anti-corrosion and long lasting.
-Energy saving working condition settable: The regenerated capacity could be set in energy saving working conditions according to the requirement for dew point, pressure, temperature etc.
- Zero consumption of regeneration: Proper design of the tower keeps 95% heat desiccant, greatly enhanced the desorption capacity of equipment, makes the regeneration more thoroughly.
-Stable quality of air source: Reverse convection drying and regeneration, avoiding the pollution of desiccant; ensure the stable quality of air source.
4. Control System:
- Human-computer interaction, remote control: color touch screen, information sharable from
distance host.
-PLS micro pc control: Use Germany Siemens PLC, with reliable and strong functions.
-Optional working conditions: Client is easily choose testing condition, summer condition, winter condition, 50% air condition, -40ºC and -20ºC dew point condition.
-Adsorption drying time (optional): we use dew point control method, 100% ensure the air quality.
-Exhaust wetness testing:
-Alarm to average pressure disorder (optional)
-Breakdown signal alarm (optional)
Technical data
Basic Technical Data Of BROATEK Desiccant Air Dryer
Heatless Desiccant Air Dryer
Heat Purge Desiccant Airy Dryer
Intake Temperature: 2~45ºC
Intake Temperature: 2~45ºC
Inlet Oil Content: ≤0.1PPM
Inlet Oil Content: ≤0.1PPM
Working Pressure: 0.6~0.95MPa
Working Pressure: 0.6~0.95MPa
Dew Point Pressure: -20~-40ºC
Dew Point Pressure: -20~-40ºC
Regeneration air capacity: ≤14%
Regeneration air capacity: ≤7%
Screw Standard: GB/T7306
Screw Standard: GB/T7306
Power Consumption: 100w
Power Consumption: 80%
Flange standard: HG20592
Flange standard: HG20592
Desiccant: Activated Alumina
Desiccant: Activated Alumina
Control Method: Micro PC Automatical
Control Method: Micro PC Automatical
Installation: Indoor Location, anchor bolt installation
Installation: Indoor Location, anchor bolt installation
Compression Heat Desiccant Air Dryer
Compressed Air Combined Type Desiccators
Intake Temperature:120~180ºC
Regeneration air capacity : ≤3%
Inlet Oil Content:≤0.1PPM
Dew Point Pressure: -40~-60ºC
Working Pressure: 0.6~0.95MPa
Pressure Loss: ≤0.05MPa
Dew Point Pressure: -12~-60ºC
Standard Cycle Period: 4~8hours
Working Cycle: 4~8 Hours
Desiccant lifetime: 3~5years
Power Consumption: 200w
Screw Standard: GB/T7306
Flange standard: HG20592
Flange standard: HG20592
Pressure Loss: ≤0.04MPa
Networking Remote Diagnosis
Regeneration air capacity : ≤1%
Control Method: Micro PC Automatical
Control Method: Micro PC Automatical
Installation: Indoor Location
Shanghai Broatek Provide various kinds of air dryers , filters and PSA nitrogen generators. Below is the
specification chart for your reference.
Heatless Desiccant Air Dryer
Model
Capacitym3/ min
Dimension mm
Inlet/outlet
Desiccant
Weight
L
W
H
Size
Weight (kg)
(kg)
BDAH-08
0.8
500
480
1320
R1/2
16
55
BDAH-17
1.7
600
540
1680
R3/4
34
78
BDAH-26
2.6
739
700
1660
R1-1/4
52
150
BDAH-38
3.8
739
700
1906
R1-1/4
72
235
BDAH-55
5.5
900
885
1880
R1-1/2
104
275
BDAH-69
6.9
950
925
1760
R1-1/2
138
336
BDAH-80
8
1024
1000
1845
DN50
170
375
BDAH-100
10
1024
1000
1995
DN50
200
420
BDAH-135
13.5
1024
1000
2320
DN50
270
480
BDAH-170
17
1200
1000
2180
DN65
300
560
BDAH-220
22
1332
1200
2345
DN65
440
740
BDAH-270
27
1382
1200
2152
DN80
570
900
BDAH-320
32
1466
1200
2150
DN80
640
1020
BDAH-370
37
1466
1200
2370
DN80
700
1140
BDAH-450
45
1633
1370
2464
DN80
870
1450
BDAH-550
55
1730
1400
2684
DN100
1060
1800
BDAH-650
65
1936
1400
2670
DN125
1340
2180
BDAH-850
85
2236
1650
2823
DN125
1600
2500
BDAH-1100
110
2280
2190
3100
DN150
2000
3200
BDAH-1300
130
2400
2200
3200
DN150
2300
3500
BDAH-1600
160
2650
2400
3400
DN150
2900
4600
BDAH-1900
190
2738
2190
3270
DN200
3400
5500
BDAH-2200
220
3146
2540
3490
DN200
4400
6900
BDAH-2600
260
3800
3000
3800
DN250
5200
8000
BDAH-3000
300
4000
3000
3800
DN250
6000
8900
Inlet Temperature: 2~50ºC Inlet oil content: ≤0.1PPM Working Pressure: 0.6-1.0MPa
Pressure Dewpoint: -40~-60ºC Regeneration air capacity: ≤14% Desiccant: Activated Alumina
Control Method: Micro Computer-Control Installation Method: Indoor Location, anchor bolt installation.
Heat Purge Desiccant Air Dryer
Model
Capacitym3/ min
Dimension mm
Electric Heat
Desiccant
Weight
L
W
H
Power(kw)
Weight (kg)
(kg)
BDAP-38
3.8
739
700
1906
1.8
72
300
BDAP-55
5.5
885
900
1880
2.6
104
410
BDAP-69
6.9
925
950
1760
3.6
138
500
BDAP-80
8
1024
1000
1845
4
160
580
BDAP-100
10
1024
1000
1995
5.1
200
655
BDAP-135
13.5
1024
1000
2320
6.5
260
690
BDAP-170
17
1200
1000
2180
7.5
300
840
BDAP-220
22
1332
1200
2345
10.8
440
1130
BDAP-270
27
1382
1200
2152
14.4
570
1245
BDAP-320
32
1466
1200
2150
16
640
1345
BDAP-370
37
1466
1200
2374
18
700
1510
BDAP-450
45
1633
1370
2464
22.5
870
1820
BDAP-550
55
1730
1400
2684
27
1060
2200
BDAP-650
65
1936
1400
2670
34.5
1340
2790
BDAP-850
85
2236
1650
2823
40.5
1600
3500
BDAP-1100
110
2280
2190
3100
51
2000
3840
BDAP-1300
130
2400
2200
3200
57
2300
4450
BDAP-1600
160
2650
2400
3400
72
2900
5200
BDAP-1900
190
2738
2190
3270
87
3400
6100
BDAP-2200
220
3146
2540
3490
111
4400
7600
BDAP-2600
260
3800
3000
3800
132
5200
8800
BDAP-3000
300
4000
3000
3800
150
6000
9700
BDAP-4000
400
4300
3200
3800
201
8000
14200
BDAP-5000
500
4500
3200
3800
252
10000
15000
air-inlet temperature: 2~50ºC Air-inlet oil carried-over:≤0.1PPM Working pressure: 0.6-1.0MPa
Dew point: -20~-40ºC Regenerative air capacity: ≤7% Desiccant: Activated alumina
Controls: PLC Installation: Indoor with Anchor bolt.
Compression Heat Desiccant Air Dryer
Model
Capacitym3/ min
Dimension mm
Cooling water
Desiccant
Weight
L
W
H
circulation T/h
Weight (kg)
(kg)
BCAD-135
13.5
1800
1600
2400
7
0.24
1000
BCAD-170
17
2000
1600
2400
8.5
0.26
1200
BCAD-220
22
2200
1600
2600
11
0.33
1600
BCAD-270
27
2400
1800
2700
14
0.45
1800
BCAD-320
32
2400
1800
2900
16
0.48
2100
BCAD-370
37
2500
1900
2900
19
0.56
2300
BCAD-450
45
2600
2000
2900
23
0.68
2700
BCAD-550
55
2600
2200
3000
28
0.83
3200
BCAD-650
65
2800
2400
3200
33
0.98
3700
BCAD-850
85
3000
2600
3200
44
1.28
4500
BCAD-1100
110
3200
3000
3400
55
1.65
5500
BCAD-1300
130
3400
3200
3400
65
1.95
6400
BCAD-1600
160
3600
3400
3400
80
2.4
7500
BCAD-1900
190
3800
3600
3400
95
2.85
9000
BCAD-2200
220
4000
3800
3600
110
3.3
10500
BCAD-2600
260
4200
4000
3800
130
3.9
12000
BCAD-3000
300
4400
4200
3800
150
4.5
13500
BCAD-4000
400
5000
4600
3800
200
6
16500
BCAD-5000
500
5600
5000
3800
250
7.5
20000
air-inlet temperature: 120~180ºC Air-inlet oil carried-over:≤0.1PPM Working pressure: 0.6-0.95MPa
Dew point: --12~60ºC Regenerative air capacity: ≤1% Desiccant: Activated alumina
Controls: PLC Installation: Indoor with Anchor bolt.
Combined Type Desiccant Air Dryer
Model
Capacitym3/ min
Dimension mm
Water
Desiccant
Weight
L
W
H
Consumption T/h
Weight (kg)
(kg)
BMAD-135
13.5
1250
1350
2000
1.7
260
770
BMAD-170
17
1350
1500
2200
2.1
340
980
BMAD-220
22
1500
1600
2400
2.6
440
1180
BMAD-270
27
1600
1700
2500
3.2
540
1400
BMAD-320
32
1680
1800
2500
3.8
640
1700
BMAD-370
37
1710
1850
2500
4.4
740
1900
BMAD-450
45
1750
1900
2650
5.4
900
2150
BMAD-550
55
1850
2000
2850
6.6
1100
2550
BMAD-650
65
2000
2200
3000
7.8
1300
2850
BMAD-850
85
2150
2300
3100
10.2
1700
3100
BMAD-1100
110
2400
2600
3200
13.2
2200
4250
BMAD-1300
130
2400
2700
3200
15.6
2600
4950
BMAD-1600
160
2600
3100
3300
19.2
3200
5500
BMAD-1900
190
2900
3500
3400
22.8
3400
6400
BMAD-2200
220
3200
3700
3600
26.4
4400
7700
BMAD-2600
260
3800
4200
3800
31.2
5200
11500
BMAD-3000
300
4000
4500
3800
36
6000
12600
BMAD-4000
400
4300
4800
3800
48
8000
16000
BMAD-5000
500
4500
5200
3800
60
10000
19000
Pressure Lose≤: 0.05MPa Standard Cycle life: 4~8hrs Desiccant life: 3~5years
Dew point: -40~60ºC Regenerative air capacity: ≤3% Desiccant: Activated alumina
Controls: PLC Installation: Indoor with Anchor bolt.
BROATEK heatless desiccent air dryer.
Shanghai Broatek is a high-tech filter manufacturer specializes in high-performance filtration products. Our product range from filter elements to post-treatment equipment for screw air compressor. We focus on continuously developing high efficiency and cost-saving products for OEMs, wholesaler and end users throughout the world.
Screw air compressor filters
With full range of replacement/retrofit filters for screw air compressor (over 10, 000 part No. ), our filter element (air filter, oil filter, air oil separators) are installed on many brand screw air compressors, most including Ingersoll-Rand, Atlas Copco, Sullair, Compair, Kaeser, Gardner Denver, BOGE, Hitachi, Kobelco, Mitsui-Seiki and Fusheng etc.
Post-treatment equipment for air compressor
Our basic product includes pipeline filtration, oil remover, desiccant compressed air dryer, refrigerated compressed air dryer, PSA nitrogen generator and self-clean air filter. All these products are made to help decreasing the damages of industrial equipment. As the compressed air contains water vapor and dust, it's a big threaten to keep machine running. Without effective control of these air during the regularly working, plug valves worn, pipeline corrupted, equipment damaged by air leakage, sometimes even caused production stagnation. Broatek is aiming at solving these problems and help our client to saving cost on maintenance.
We value sustainable relationships with our employees, customers and partners based upon honest dealings, mutual satisfaction and respect.